IMAGING DIAGNOSTICS

Syringeless CT Contrast Media Injector

Once-daily setup and 24-hour multiple

Patient use pump tubing-flex*

More than 30 years of roll pomp injector experience
*Or 19 bottles of a contrast medium, whichever comes first

German innovation and workflow efficiecies

Syringeless Contrast Media Injector 03

Integrated CM heat retainers to maintain CM tempreature in container

Media container holder for saline (NaCl) Optional: Saline rod

Media detectors with status indicators

Display unit for simple, safe and quick operation

Pressure sensors

Patient tubing air detector

Pump tubing-flex air detectors with status indicator

Available as a mobile pedestal version or with a 3D ceiling mount.

Used in CT procedures for the delivery of Omnipaque (ihexol) Injection contrast medium from GE Healthcare as supplied in Imaging Bulk Packaging*

Tubing System

The tubing system consists of pump tubing-flex, spike for CT and patient tubing

Pump tubing-flex

24 hour multiple patient use

The pump tubing-flex is cleared for 24 hour usage or a maximum of 19 contrast media bottles, whichever comes first.

Pump tubing flex

Swabable valve

Connection point for patient

tubing to help prevent contamination

(aseptic procedure)

Check valve

Swabable valves

Connection point for

spikes to provide a

hygienic security barrier

for the media input

(aseptic procedure)

Pressure sensor unit with

integrated particle filter

Spike for CT (CM/NaCl)

Single-bottle use (max. 8 hours)

Two spikes to be used with contrast media in Imaging Bulk Package and one to be used with the saline (NaCl) container/bag.

Spike for CT

Integrated air filter

Patient tubing

250 cm | 320 cm

Simple-patient use (max. 12 hours)

The patient tubing connects the pump tubing-flex to the cannula on the patient and transports media from the pump tubing-flex to the patient.

Pacient Tubing

Double check valve system

Double check valve system

Overview of technical information

Dimensions (LxWxH)Pedestal version: 25.39in x 25.39in x 45.08in (645mm x 645mm x 1445mm)
WeightWeight
Power SupplieRechargeable battery and mains operation
Voltage Supplie (Battery Charging)Voltage rating 100 - 240 VAC / 50/60 Hz (Automatic)
Media TransportRoll pump
Flow Rate (with contrast media)0.1 to 10.0 mL/patient, in increments of 10.1 mL/s
Maximun Injection Volume400mL/Patient, in increments of 1.0 mL/s
Reservoir VolumeContrast media: max. 2 x 500 mL (300/350 mgl/mL IBP) NaCl: max. 1 x 2,000 mL (pedestal version) NaCl: max. 1 x 1,000 mL (ceiling version)
Heat RetainerContrast media heat retainer (> 28°/> 82.4°F to 37°C/98.6°F)
Maximun System PressureSetting: 2 - 13.5 bar (29 - 195.8 psi) Effective: up to 17 bar (246.6 psi)
Air Monitoring3 detectors for the media supply tubing, 1 detector for the pump tubing-flex, 1 detector for the patient tubing
Pressure Monitoring 2 pressure sensors
User Interfaces Terminal: 12” Color monitor with PCAP multi touch. Injector: Graphical display with soft keys
Data Import and ExportUSB interface
Data Transfer from Injector to TerminalBluetooth, power class 1
Number of Boli (Phases) per Injection ProgramMax. 40
Number of Injection Programs that can be SolvedUp to 100
Pressure Curve Real-time display of the injection pressure curve
Software functions (standard)CM-Loop: Two-way switchover when there are two identical contrast media. Remainder display. NaCl backup. Manual pause/time-controlled pause. Keep Vein Open (KVO)
Software OptionsSame patient: Multiple injections per pacient. Elapsed time: Time since end of injection (0 - 999 sec.). Stopwatch: Before and after each bolus (0 - 999 sec.). CM substitution
Injector AccesoriesTray, waste bin, saline rod, drip cup
DisposablesSpike for CT. Pump tubing-flex. Patient tubing (98 in or 126 in/250 cm or 320 cm)
Over a century of innovation

Subject to technical changes, typographical errors and other errors.

Your complete customer solution